TÜV SÜD Test Report TC.26.04.002098 – DVM 1 × 1 m Fire Blankets
TÜV SÜD Fire Blanket Test Report TC.26.04.002098
DVM 1 × 1 m Fire Blankets | EN 1869:2019 | Class F Cooking-Oil Fire Performance
Independently tested. Documented results. Not merely a declaration of compliance.
DVM International B.V., manufacturer of the DVM fire blanket series, commissioned independent testing of its 1 × 1 m fire blankets by TÜV SÜD in accordance with EN 1869:2019.
The testing included actual cooking-oil fire performance tests, heptane fire tests, construction requirements, general performance, electrical resistance, marking and traceability.
The official results are documented in TÜV SÜD Test Report TC.26.04.002098, issued on 9 June 2026.
Verify the Authenticity of Our TÜV SÜD Test Report
Don't just trust a claim. Verify the test.
DVM International B.V. provides direct access to the official TÜV SÜD report verification system. Customers, professional buyers and inspectors can independently check the authenticity of our test report directly through TÜV SÜD.
The verification link opens the official TÜV SÜD North Asia verification platform, where the report number and unique security code are automatically provided.
Report number: TC.26.04.002098
Issue date: 9 June 2026
Applicant: DVM International B.V.
Test standard: EN 1869:2019
Verify Test Report Directly at TÜV SÜD
This link opens an external website operated by TÜV SÜD. The report is independently accessible through the official TÜV SÜD verification system. Verification of the report's authenticity does not constitute separate product certification or ongoing production surveillance.
Class F Cooking-Oil Fire Performance: Independently Tested
Cooking-oil and fat fires are classified as Class F fires. Demonstrating performance against this type of fire is particularly important for fire blankets intended for kitchen applications.
DVM does not rely solely on a manufacturer's statement that its fire blankets comply with EN 1869:2019. The DVM 1 × 1 m fire blanket series has undergone actual fire-performance testing by TÜV SÜD.
During the cooking-oil fire test, TÜV SÜD used 3 litres of edible cooking oil. Two test specimens were evaluated.
- Both specimens successfully extinguished the cooking-oil fire.
- No visible flames remained after removal of the fire blankets.
- No re-ignition occurred within the specified three-minute observation period.
- Both fire blankets remained intact and did not ignite during testing.
- Both specimens received a PASS conclusion.
These results provide independently documented evidence of the tested DVM fire blankets' performance against cooking-oil fires (Class F) under the specified EN 1869:2019 test conditions.
Source: TÜV SÜD Test Report TC.26.04.002098, page 5, section 2.3.
Watch the Actual TÜV SÜD Fire Tests
The following videos show fire-performance tests conducted during the independent evaluation of the DVM 1 × 1 m fire blanket series. The official written report provides the complete test conditions, criteria and results.
TÜV SÜD Cooking-Oil Fire Test
Actual fire-performance testing with burning cooking oil, demonstrating the tested fire blanket's performance against a Class F cooking-oil fire.
TÜV SÜD Heptane Fire Test
Actual fire-performance testing using heptane fuel, providing additional independent evidence of fire-suppression performance under controlled conditions.
Download Official TÜV SÜD Test Report TC.26.04.002098
The complete ten-page TÜV SÜD test report is available for independent review. It documents the tested specimens, applicable requirements, test methods and reported results.
Download TÜV SÜD Test Report (PDF)
Report number: TC.26.04.002098
Issue date: 9 June 2026
Applicant: DVM International B.V.
Tested standard: EN 1869:2019
Summary of TÜV SÜD Test Results
The official report records passing conclusions for the applicable construction, general performance, fire-performance, marking and traceability requirements.
| Test / Requirement | Reported Result |
|---|---|
| Construction requirements | PASS |
| General performance | PASS |
| Cooking-oil fire performance | PASS |
| Heptane fire performance | PASS |
| Electrical resistance | ≥ 1 MΩ — PASS |
| Ready for use within 4 seconds | PASS |
| Marking requirements | PASS |
| Traceability requirements | PASS |
Results are summarised from the official TÜV SÜD report, pages 3–9. For the exact requirements and evaluation criteria, consult the complete report.
Heptane Fire Performance Test
TÜV SÜD also evaluated the DVM 1 × 1 m fire blanket series using a controlled heptane fire test.
The test used 3 litres of heptane and 1 litre of water. Both tested specimens met the applicable extinguishing requirements.
No visible flames remained after removal of the blankets, and no re-ignition occurred within the specified ten-second observation period.
Both specimens received a PASS conclusion.
Source: TÜV SÜD Test Report TC.26.04.002098, page 6, section 2.4.
GARAN 10-Year Manufacturer's Warranty
In addition to independent TÜV SÜD testing, DVM International B.V. provides its own GARAN 10-Year Manufacturer's Warranty for eligible DVM fire blankets.
GARAN is a manufacturer's warranty issued by DVM International B.V. and is separate from the independent testing performed by TÜV SÜD. Warranty coverage is subject to the applicable GARAN terms and conditions.
Click a GARAN label to view the full-size version. The GARAN warranty is provided by DVM International B.V., not by TÜV SÜD.
DVM 1 × 1 m Fire Blanket Models Covered by the Test Documentation
The official TÜV SÜD report identifies DVM fire blanket models including DVM-FBAG-1x1 and DVM-FBOX-1x1.
Both models belong to the DVM 1 × 1 m fire blanket series, with different protective container configurations.
Explore All DVM Fire Blankets →
Independent Testing and Manufacturer Accountability
DVM International B.V. is the manufacturer responsible for the DVM fire blanket series and its associated product documentation.
By commissioning independent testing and making the complete TÜV SÜD report publicly accessible, DVM enables professional buyers, safety specialists, inspectors and end users to examine the documented test evidence directly.
The report provides test evidence for the identified specimens under the specified test conditions. It is not presented as evidence of continuous TÜV SÜD production surveillance or a separate product certification.
Further Documentation for Buyers, Users and Inspectors
DVM provides additional technical and practical documentation to support product selection, safe use, procurement and periodic inspection.
- Buyers: Reference guides, RFQ documentation and product evaluation resources.
- Users: Fire blanket instructions and application guidance.
- Inspectors: Periodic inspection checklists and documentation resources.
Additional Fire Blanket Information
For more information about EN 1869:2019, Class F fires, fire blanket selection, safe deployment and maintenance, consult our additional resources.